Healthy Indoors Magazine - USA Edition

HI Feb 2019

Healthy Indoors Magazine

Issue link: https://hi.healthyindoors.com/i/1088111

Contents of this Issue

Navigation

Page 27 of 72

28 | February 2019 Air quality instrumentation Part II: A manufacturing standard By David Pariseau I n the previous installment I provided a brief history of air quality in the cleanroom space. Essentially briefly chronicling the rapid rise of instrumentation followed by a need for standards to control the manufacturing of these instruments so they could better suit the in- dustry they were serving. In this installment we'll look a bit more closely at the ISO standard (specifically ISO 21501-4) that emerged. We'll go through each of the requirements and discuss why this was included and what it sought to control. Ultimately, we're attempting to lay the groundwork for a similar effort vis-à-vis air quality sensors in the air quality space. The hope is that understanding de- velopments in industrial air quality monitoring will serve as a useful starting point. ISO 21501-4 (or part 4) applies specifically to "Light scattering airborne particle counters for clean spaces". There are certainly other ways to measure air quality, and in indoor and outdoor air quality most of the sensors are not particle counters, but it's still instructive to use this stan- dard point in discussing what an air quality instrument stan- dard should address. ISO 21501-4 has 11 basic requirements specified in and in order for an instrument to be compliant it must implement or pass all of these requirements. We'll add each of these requirements in turn and attempt to explain the requirement, why it's important and finally how it might apply to indoor or outdoor air quality measurement products. In order to understand the standard it's important to first define what a particle counter is. I think we've all had the experience of looking through a sunlit room and seeing particulates suspended in the air, caught in a sunbeam. A particle counter typically uses a very thin laser beam and passes the particulates through it essentially one at a time. As the particulates pass through the beam they scatter light with some of that light hitting a sensitive optical de- tector, the tiny signal from that detector is amplified into an electrical pulse, the height of that pulse corresponding very closely to the size of that particulate. The height of each of these pulses is measured and then particles are binned by size and counted. At the end of the sample the counts in each bin (or channel) are reported. In air quality applications, these counts are converted into an estimate of mass for each channel. In the figure to the right the air would enter the sensor through the inlet and exit through the outlet, as the air exits the inlet it passes through a laser beam (shown in red) and particulates would scatter light onto a detector (round object below it). In air quality applications there are also sensors that measure aggregate mass instead of counting particulates. This is akin to taking a small portion of that sunlit room and looking at all the particles in that area and attempting to estimate the mass of the whole in one shot. They typically do this by measuring the scattered light of all the particles passing through the sensor over some period. They then as- sume that the particles that passed through the sensor over that period follow some regular size distribution (sometimes but not always the case) and then compare the result to a number of values recorded during calibration to arrive at an

Articles in this issue

Archives of this issue

view archives of Healthy Indoors Magazine - USA Edition - HI Feb 2019